Surface resistance/resistivity
With circular electrode or polymeric blade electrode (Bayer electrode). Documentation in report as direct result (depending on electrode) and surface resistivity. Conditioning as agreed, measurements even under conditions deviating from the standard climate of 23°C/50% r. h. possible in climate chamber.
Film, paper: sample over total width of material, minimum length: 0,2 m, other samples, per single measurement: min Ø 80 mm (circular electrode) or 100 mm x 30 mm (polymeric blade electrode)
Standardprüfungen
surface resistance DIN EN 62631-3-2 (hist DIN IEC 60093) Measurement of the surface resistance after conditioning (96 h) under standard climate (23°C/ 50% r.h.) Norm: DIN EN 62631-3-2 (VDE 0307-3-2)
surface resistance TRGS 727-at 23°C/ 30 % r. F. Measurement of the surface resistance in analogy to DIN EN 62631-3-2 (VDE 0307-3-2 ) with the parallel polymer blade electrode ("Bayer"- electrode) after conditioning (96h) under "dry" climate (23°C/30% r.h.) Norm: TRGS 727
surface resistance TRGS 727 Measurement of the surface resistance in analogy to DIN EN 62631-3-2 (VDE 0307-3-2 ) with the parallel polymer blade electrode ("Bayer"- electrode) after conditioning (96h) under standard climate (23°C/50% r.h.) Norm: TRGS 727