Opacity measurement
The measurements are carried out using a spectrophotometer according to ISO 2471 or DIN 6125. An opacity card (Leneta) type 2 a serves as a black and white base according to DIN 6125.
Opacity, opaque and/or white pigmented films Method using diffuse reflection, with Leneta opacity card as background. By default, measurements are performed with standard light type D65 under gloss inclusion (SCI). On request, measurements with standard light type D 50 and/or under gloss exclusion (SCE) are also possible. Norm: DIN 6125
Opacity, paper and cardboard Method using diffuse reflection. Ro is measured against a black hollow body, R∞ is measured against a lightproof material stack. By default, measurements are performed with standard light type D65 under gloss inclusion (SCI). On request, measurements with standard light type D 50 and/or under gloss exclusion (SCE) are also possible. Norm: ISO 2471