Tensile test aluminium films
DIN EN 546-2 determination of tensile strength RM, max. load Fmax, elongation at break A100 oder A50 (accredited test method)
Approx. 0,1 - 0,2 m² or 2 DIN A 4 sheets, minimum sample width resp. length 150 mm, optimum: small reel or hand roll without folds and kinks
Standardprüfungen
tensile test alumiuim foils A 100 (initial gauge 100 mm) Tensile test of aluminum foils with a initial gauge (gauge length) of 100 mm with a crosshead speed of 10 mm / min (10% / min).
tensile test alumiuim foils A 50 (initial gauge 50 mm) Tensile test of aluminum foils with a initial gauge (gauge length) of 50 mm with a crosshead speed of 5 mm / min (10% / min).